Residual Current Devices
Electricity has undoubtedly become an indispensable part of everyday life for everyone. But although it enables us to use thousands of new devices and technologies, it can be hazardous if not treated with caution. The voltage of the electricity used by appliances is enough for them to operate normally, but in many cases it can be lethal to the human body. Everyone must protect against accidental electrical contact and this is the purpose of residual current devices. When they hear of the concept of residual current devices for the first time, many people will probably wonder what it is and if there is any such thing as faulty electricity. Residual current devices are obligatory in practice in order to comply with modern health and safety standards when working with electricity. Below you will find out exactly what residual current devices are and why they are so important for you and your home.
Functions of residual current devices
The main purpose of residual current devices is to prevent accidents at home and to protect the human body. This type of device is designed to cut off the power supply at a number of crucial moments for human health and the safety of property. Here are the main functions of residual current devices and the situations in which they are used:
- protecting people from hazardous contact with electricity in the event of damaged conductor insulation - 30 milliamps.
- protecting real property from the outbreak of fire - between 300 and 500 milliamps
- cutting off the power circuit under load in the event of a short circuit or overload. This can protect both every consumer and the entire switchboard. Such a feature will only be available if you combine a residual current device with a circuit breaker.
Applying and selecting residual current devices
Residual current devices are widely applied and can be found in almost all utilities and production sites. In addition to protecting people from electrocution, the residual current device effectively protects your home from fire. It is important to select the right residual current device for the power rating of the consumer appliances and for the leakage current.
ElmarkStore residual current device
The ElmarkStore product range includes residual current devices that will ensure the safety required when working with electricity. We have several types of residual current devices available: bipolar, quadripolar and combined. On the other hand, you can choose between electronic and electromagnetic residual current devices, which differ in their current rating, leakage current, sensitivity and other important technical characteristics.
To protect your home and family or your office and business premises, choose the appropriate ElmarkStore residual current device!
Functions of residual current devices
-
NEW
to the product
ELECTROMAGNETIC RCBO JEL5A 6KA 2P 6A/30MA 40006A
- Brand 
Rated voltage 240 V Rated current 6 A Breaking capacity 6 kA Leakage current 30mA Warranty -
NEW
to the product
ELECTRONIC DPN RCBO JEL9A 6kA 2P 10A/30mA 40501A
- Brand 
Rated voltage 240 V Rated current 10 A Breaking capacity 6 kA Leakage current 30mA Warranty -
NEW
to the product
ELECTRONIC DPN RCBO JEL9A 6kA 2P 16A/30mA 40502A
- Brand 
Rated voltage 240 V Rated current 16 A Breaking capacity 6 kA Leakage current 30mA Warranty -
NEW
to the product
ELECTRONIC DPN RCBO JEL9A 6kA 2P 20A/30mA 40503A
- Brand 
Rated voltage 240 V Rated current 20 A Breaking capacity 6 kA Leakage current 30mA Warranty -
NEW
to the product
ELECTRONIC DPN RCBO JEL9A 6kA 2P 25A/30mA 40504A
- Brand 
Rated voltage 240 V Rated current 25 A Breaking capacity 6 kA Leakage current 30mA Warranty -
NEW
to the product
ELECTRONIC DPN RCBO JEL9A 6kA 2P 32A/30mA 40505A
- Brand 
Rated voltage 240 V Rated current 32 A Breaking capacity 6 kA Leakage current 30mA Warranty -
NEW
to the product
ELECTRONIC DPN RCBO JEL9A 6kA 2P 40A/30mA 40506A
- Brand 
Rated voltage 240 V Rated current 40 A Breaking capacity 6 kA Leakage current 30mA Warranty -
NEW
to the product
ELECTRONIC DPN RCBO JEL9A 6kA 2P 6A/30mA 40500A
- Brand 
Rated voltage 240 V Rated current 6 A Breaking capacity 6 kA Leakage current 30mA Warranty -
NEW
to the product
ELECTRONIC RCBO JEL4A 6kA 2P 10A/300mA 40208A
- Brand 
Rated voltage 240 V Rated current 10 A Breaking capacity 6 kA Leakage current 300mA Warranty -
NEW
to the product
ELECTRONIC RCBO JEL4A 6kA 2P 10A/30mA 40211A
- Brand 
Rated voltage 240 V Rated current 10 A Breaking capacity 6 kA Leakage current 30mA Warranty -
NEW
to the product
ELECTRONIC RCBO JEL4A 6kA 2P 16A/300mA 40235A
- Brand 
Rated voltage 240 V Rated current 16 A Breaking capacity 6 kA Leakage current 300mA Warranty -
NEW
to the product
ELECTRONIC RCBO JEL4A 6kA 2P 16A/30mA 40215A
- Brand 
Rated voltage 240 V Rated current 16 A Breaking capacity 6 kA Leakage current 30mA Warranty -
NEW
to the product
ELECTRONIC RCBO JEL4A 6kA 2P 20A/300mA 40230A
- Brand 
Rated voltage 240 V Rated current 20 A Breaking capacity 6 kA Leakage current 300mA Warranty -
NEW
to the product
ELECTRONIC RCBO JEL4A 6kA 2P 20A/30mA 40225A
- Brand 
Rated voltage 240 V Rated current 20 A Breaking capacity 6 kA Leakage current 30mA Warranty -
NEW
to the product
ELECTRONIC RCBO JEL4A 6kA 2P 25A/300mA 40246A
- Brand 
Rated voltage 240 V Rated current 25 A Breaking capacity 6 kA Leakage current 300mA Warranty -
NEW
to the product
ELECTRONIC RCBO JEL4A 6kA 2P 25A/30mA 40240A
- Brand 
Rated voltage 240 V Rated current 25 A Breaking capacity 6 kA Leakage current 30mA Warranty -
NEW
to the product
ELECTRONIC RCBO JEL4A 6kA 2P 32A/300mA 40236A
- Brand 
Rated voltage 240 V Rated current 32 A Breaking capacity 6 kA Leakage current 300mA Warranty -
NEW
to the product
ELECTRONIC RCBO JEL4A 6kA 2P 32A/30mA 40265A
- Brand 
Rated voltage 240 V Rated current 32 A Breaking capacity 6 kA Leakage current 30mA Warranty -
NEW
to the product
ELECTRONIC RCBO JEL4A 6kA 2P 40A/300mA 40273A
- Brand 
Rated voltage 240 V Rated current 40 A Breaking capacity 6 kA Leakage current 300mA Warranty -
NEW
to the product
ELECTRONIC RCBO JEL4A 6kA 2P 40A/30mA 40274A
- Brand 
Rated voltage 240 V Rated current 40 A Breaking capacity 6 kA Leakage current 30mA Warranty